National Repository of Grey Literature 2 records found  Search took 0.00 seconds. 
Accuracy of non-contacting Temperature Measurement
Horák, Ladislav ; Janečka, Jan (referee) ; Vdoleček, František (advisor)
This master’s thesis is specialized on the influence of correct parameters of emissivity, which depends on the temperature, wavelength and ambient environment. The investigation the parameter was taken infrared non-contact thermometer MI3 from company Raytek. To improve the quality of measurement was designed and programmed measuring utility program. The program was developed in the LabView 8.5 programming environment. To obtain the true value of the measured temperature of the target was designed and constructed the touch thermometer with the resistance dependent sensor. The thermometer is connected to the communication box of infrared thermometer and contain the same program. Nowadays are the most advanced IR thermometer with fixed parameters emissivity, which is applicable just to the real body in the vicinity of the parameter emissivity 0,95. For those IR thermometers were designed correction function, which would have temperature measured at a fixed emissivity parameter 0,95 set close to the actual value of the object.
Accuracy of non-contacting Temperature Measurement
Horák, Ladislav ; Janečka, Jan (referee) ; Vdoleček, František (advisor)
This master’s thesis is specialized on the influence of correct parameters of emissivity, which depends on the temperature, wavelength and ambient environment. The investigation the parameter was taken infrared non-contact thermometer MI3 from company Raytek. To improve the quality of measurement was designed and programmed measuring utility program. The program was developed in the LabView 8.5 programming environment. To obtain the true value of the measured temperature of the target was designed and constructed the touch thermometer with the resistance dependent sensor. The thermometer is connected to the communication box of infrared thermometer and contain the same program. Nowadays are the most advanced IR thermometer with fixed parameters emissivity, which is applicable just to the real body in the vicinity of the parameter emissivity 0,95. For those IR thermometers were designed correction function, which would have temperature measured at a fixed emissivity parameter 0,95 set close to the actual value of the object.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.